FAQ
Get fast answers about Vaczon ceiling fans: choosing the right size, installation tips, remote use—so you enjoy smooth, quiet comfort year-round.
Orders
Below are some of are common questions about orders
Shipping costs for freight and express shipments are based on point-to-point calculations, taking into account weight, distance and shipping method. Additional charges for freight shipments may apply.
You will not be charged sales tax.
Vaczon accepts all major credit cards, including Visa, Mastercard, American Express and Discover cards.
In addition to accepting credit cards, Vaczon accepts payment through PayPal.
After the ceiling fan is finish processing, you can track the status of the package online within about 2-3 business days.
Shipping & Returns
Below are some common questions about shipping, returns, and exchanges
Generally, Vaczon accepts returns for up to 30 days from the date of shipment. Products being returned must be new and in their original sealed packaging. Other restrictions apply. Please refer our Return Policy for more information. For information products that are defective or were damaged during shipment, please refer our damaged and defective goods section of our Return Policy.
Vaczon proudly stands behind all products we sell. When you meet a defect in materials or workmanship when purchase within one year, we will repair or replace your product. Certain exclusions do apply, so please see our Warranty Policy for more details.
There are many handmade fixtures we are selling on Vaczon, for this kind of products,the processing time will be a little longer than others,which will be about 15 business days after payment. For other fixtures, the processing time will be about 7 business days. We will email you after you place the order and inform you the specific processing time.
Vaczon owns different warehouses, orders of two or more items may result in multiple separate shipments. Your order may arrive as several shipments on different days. No additional charge from your side.
Products
Below are some common questions about our products
The maximum installation angle of fans with downrods sold on the website is 15°. If it exceeds 15°, you need to go to the store to buy a suitable adapter. The website does not sell such parts.
If the product supports color temperature adjustment, you can adjust the color temperature by continuously pressing the light button.
No, it is best to use it with the downrod that comes with the fan, otherwise it will affect the use of the fan.
No, if the fan is controlled by a remote control, please control it directly with the remote control. It is not recommended to use wall controls (including dimmable or adjustable speed wall controls) because the use of wall controls can affect the use of the fan because it may interfere with the fan's built-in controls. The fan is designed to be used with the included remote control for optimal performance.
1-Make sure that the connection between the fan down rod with the motor and mounting bracket is secure.
2-Check that all blade and blade arm screws are secure.
3-Most fan wobbling problems are caused when blade levels are unequal. Check this level by selecting a point on the ceiling above the tip of one of the blades. Measure this distance. Rotate the fan until the next blade is positioned for measurement. Repeat for each blade. The distance deviation should be equal within 1/8"(0.32cm).
4-Use the Blade Balancing Kit if the blade wobble is still noticeable.
5-If the blade wobble is still noticeable, interchanging two adjacent (side by side) blades can redistribute the weight and possibly result in smoother operation.
If you still can't solve your problem after trying the measures, please send the video to Support@vanub.com, we will help you solve the problem after asking the technicians, please don't worry.
1-take off the light kit first and start the fan. If there is no noise, check for loose light fixtures and fan connections
2-Remove the light kit, start the fan, remove the leaf frame and fan blades if the noise still exists, and run the motor idling. If the motor does not make a noise, you need to check whether the blade holder is installed in place
3-If the motor is still making noise when idling, the motor needs to be replaced
If you still can't solve your problem after trying the measures, please send the video to Support@vanub.com, we will help you solve the problem after asking the technicians, please don't worry.
If the fan can adjust the color temperature, you can adjust the color temperature of the light by continuously pressing the light button.
Please determine the fan motor first, Please do not use wall control. If you use wall control, please remove it before testing. Thank you.
1- Check the main and branch circuit fuses or breakers.
2- Ensure the remote is within the 20 foot range of the receiver and check batteries to insure they are good and oriented correctly.
3- Check to make sure the frequency switches (DIP Switches) from the remote to the receiver are set to the same frequency.
4- To reset the remote control: 1) Turn off power to fan. 2) Remove batteries from remote. 3) Wait 10 seconds. 4) Replace batteries and turn power on.
5- If using a Variable Speed Wall Switch, ensure it is specifically designed for use with a ceiling fan.
6- Check the line wire connections to the fan and the switch wire connections in the switch housing per the instructions.
7- (AC motor) Check if the fan can work properly while bypassing the receiver box.
Or (DC motor) Check if the receiver box has power output to the fan.
Please follow the steps below to troubleshoot.
1. Whether a dimmable or adjustable speed wall control is used.
2. Is the light bulb installed correctly?
3. Whether the light bulb is a good light bulb/whether a dimmable light bulb is used.
4. Check the wiring (light panel wiring, receiver light wire).
5. Confirm whether it is a receiver failure or a lamp failure.
1- Check whether the ceiling is uneven or not
2-Whether the hangers are installed horizontally
3-Check whether the two screws of the hanger holding the hanging clock are one long and one short, which affects the horizontal installation.
A: Matters needing attention1. This product is only used for on/off and speed control of interior ceiling fans (including lamps), and on/off control of ceiling fan lamps.
This product is only used for on/off and speed control of interior ceiling fans (including lamps), and on/off control of ceiling fan lamps. To avoid overheating and damage to other equipment, do not use for control sockets, motor control equipment, or transformer powered equipment. This product is only used to control a single ceiling fan and lighting combination.
2. Second, the transmitter and receiver code
If there are two or more ceiling fans installed in the same house, in order to prevent your ceiling fans from being affected by the remote control of the adjacent ceiling fans, first turn the switch in each remote control transmitter to the CODE position (see the schematic diagram FIG1) Remarks: The standard state of the transmitter is in the common code COM.
After installing the remote control receiver on the ceiling fan
1: Turn on the power of the 1# ceiling fan receiver (the power of the 2# receiver is kept in a power-off state), within 30 seconds after the fan power is turned on, press the LEARN button corresponding to the 1# transmitter, then The receiver will learn the transmitter code. When the transmitter code is learned successfully, the light of the receiver will flash twice, and then it can be used normally.
2: Turn on the power of the 2# ceiling fan receiver (the power of the 1# receiver is kept in a power-off state), within 30 seconds after the fan power is turned on, press the LEARN button corresponding to the 2# transmitter, then The receiver will learn the transmitter code. When the transmitter code is learned successfully, the light of the receiver will flash twice, and then it can be used normally. And so on, only one ceiling fan is powered on each time the corresponding transmitter learns. After the 1# and 2# remote control transmitters have been successfully learned, turn on the power of both ceiling fans. At this time, the 1# transmitter and the 2# transmitter can be used independently for one ceiling fan.